- Zenith 750 w/ 915 (✔)
- >
- Fuselage Mounted Kits - 915is & 916is
- >
- Special Constant Duty Master Solenoid & Nylon Insulator Assembly Kit - 912is, 915is, 916is
Special Constant Duty Master Solenoid & Nylon Insulator Assembly Kit - 912is, 915is, 916is
SKU:
SFF 40AKis/5
$161.24
$161.24
Unavailable
per item
The Starter Solenoid Assembly Kit includes the Insulating Block for your Starter Solenoid, the CAD-plated mounting Hardware for the starter Solenoid and Master Solenoid, and the Insulated Jumper.
INSTALLATION INSTRUCTIONS
STEP 1:
Layout as shown below for bare firewall.
Layout holes as per below for partly assembled fire wall.
Place Nylon Insulator as shown using previously drawn lines as a corner guide.
Mark the top two holes.
Then take off the insulator.
NOTE: If you are installing the 914 version, there is no nylon insulator. Simply assemble the rest of the kit and back-drill the holes through the firewall based on the right-hand solenoid.
Mark the top two holes.
Then take off the insulator.
NOTE: If you are installing the 914 version, there is no nylon insulator. Simply assemble the rest of the kit and back-drill the holes through the firewall based on the right-hand solenoid.
STEP 2:
Drill 4 #10 holes. Drill the two holes you just marked in the above photo, and two at 153 mm and 95 mm marks you made in step 1.
STEP 3:
Deburr and install Solenoids & Insulator as shown below.
NOTE: The extra long bolt on the left-hand side (below the screwdriver) is for a ground.
NOTE: The extra long bolt on the left-hand side (below the screwdriver) is for a ground.